Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arch. cardiol. Méx ; 93(4): 391-397, Oct.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527715

RESUMO

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

2.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1249911

RESUMO

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Animais , Masculino , Feminino , Coelhos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents Farmacológicos , Desenho de Prótese , Espectrofotometria Infravermelho , Suínos , Seguimentos , Modelos Animais de Doenças , Microscopia
3.
Arch. cardiol. Méx ; 90(2): 142-147, Apr.-Jun. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1131023

RESUMO

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Humanos , Animais , Cães , Coelhos , Desenho de Prótese , Stents , Vasos Coronários/cirurgia , Doença da Artéria Coronariana/cirurgia , Fluoroscopia , Ligas de Cromo/química , Modelos Animais
4.
Arch. cardiol. Méx ; 90(1): 48-55, Jan.-Mar. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131005

RESUMO

Abstract One-third of the population in intensive care units is in a state of circulatory shock, whose rapid recognition and mechanism differentiation are of great importance. The clinical context and physical examination are of great value, but in complex situations as in cardiac care units, it is mandatory the use of advanced hemodynamic monitorization devices, both to determine the main mechanism of shock, as to decide management and guide response to treatment, these devices include pulmonary flotation catheter as the gold standard, as well as more recent techniques including echocardiography and pulmonary ultrasound, among others. This article emphasizes the different shock mechanisms observed in the cardiac care units, with a proposal for approach and treatment.


Resumen Un tercio de la población de pacientes en unidades de cuidados intensivos se encuentran en choque circulatorio, el identificarlo y determinar su mecanismo de manera rápida y eficaz es de gran importancia. El contexto clínico y el examen físico son de gran utilidad, sin embargo existen situaciones de alta complejidad en las que se requiere del uso de las distintas modalidades de monitorización hemodinámica avanzada, tanto para determinar la causa, como para decidir el manejo y guiar respuesta al tratamiento, incluyendo el catéter de flotación pulmonar como gold standard, así como técnicas más recientes incluyendo ecocardiografía y ultrasonido pulmonar, entre otros. Este artículo enfatiza los distintos mecanismos de choque observados en las unidades de cuidados cardiacos, con propuesta de abordaje y tratamiento.


Assuntos
Humanos , Choque/fisiopatologia , Unidades de Cuidados Coronarianos , Hemodinâmica/fisiologia , Choque/terapia , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Ecocardiografia/métodos , Ultrassonografia/métodos
5.
Rev. invest. clín ; 72(1): 32-36, Jan.-Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1251832

RESUMO

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Desenho de Prótese , Stents , Isquemia Miocárdica/cirurgia , Projetos Piloto , Seguimentos , Ultrassonografia , Resultado do Tratamento , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , México
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA